2/4 Hours Vertical Shutter
4
Hours Horizontal Escalator
4
Hours Lateral / Sliding Shutters
6 Hours Folding / Sliding
Shutters
Explosion proof
Shutters
Double
wall Insulated Fire Shutters
|
2
& 4 Hours Vertical Fire Rated Shutters
|
 |
|
 |
|
Specifications
Supply and insulation of
SKB 2hours rated motorized roller shutter c/w SKB-A1 galvanized
steel curtain slats with Nylon end, 3.0mm thick
galvanized steel powder coated guide with Silencer
belts. Bottom bar & Guides to be powder coated to
standard RAL colour to manufacturer's specifications.
Fire shutter design shall confirm to BS 476 Part 22 and
approved , accepted by local Fire department.
Size : 7000mm W x 3000mm H.
|
|
| Optional
features |
 |
|
|
-
Electric
releaser-Gravity close design. Upon receive of
fire signal, the shutter shall close by gravity
and do not need any power from the Motor unit
-
Thermal
fusible link Auto close by room temperature
above 68 degree Celsius.
-
Delay
Timer
,time range from 60
sec to 20 min. Able to delay the fire shutter to
close down to a pre-set time range to allow for
evacuation.
-
Audible
alarm & warning flashing.
-
Bottom
safety sensor edge-prevent overrun if obstruction
during closing of shutters.
-
Belt
Silencer in Guide rails to reduce noise and smooth
in operation.
-
Anti
wind design Guide rails-U75W able to withstand
high velocity wind load.
-
Guide
rail in Stainless steel SUS 304 Hairline Finish.
-
Stainless
steel or Aluminum covered Bottom Bar.
-
Stainless
steel or Aluminum ceiling Support frame.
-
Curtain
slats or RAL Powder Coated colour or stainless
steel.
|
|
|
Guide
Rail

|
 |
|
|
Shutter
curtain slat Model:SKB-A7
|
Shutter
curtain slat Model:SKB-A1
|
Bottom
bar with guided Model:T120N
|
|
|
|
|
|
|
|
| Explosion
Proof Roller Shutters
|
|
|
With rapid growing in the Petro-Chemical Industries and
Chemical premises in Asian Countries. The increase
requirement for the safety operations of the plants is
essential. Doors and Shutters are highly requested to
resistance for Blast pressure and prevention of explosion. With
overseas technical support.
For Petrochemical plant and gas processing which require
flame and gas proof security.
Ferco Shutters are ready for Supply and Installation of
such products to serve the needs.
|
 |
|
|
|
 |
|
4
Hours lateral / Sliding Fire Rated Roller Shutters |
 |
 |
|
Path winder laterally sliding fire shutters allows
unrestricted access around atriums & stairwells. It
has the advantage of being able to follow any contoured
paths
of 600mm radius,
over large distances, without any bottom guides.
A single Path winder has a considerable span of maximum
40 meters. |
|
|
| Multiple
installations allow larger span area to be protected. Very
suitable for fire protection for shopping center
atriums, stairwells factories, warehouses which
require wide openings without columns in between. |
|
|
 |
| Special
Features |
 |
 |
-
Reliable
-
Safety
-
Smooth
-
A
technology breakthrough for fire compartment
design.
-
Great
flexibility designing without columns in between
-
Ideal
for shopping center atrium design fire safety.
-
No
bottom guide needed.
|
 |
|
 |
|
|
|
|
|
6
Hours Fire Rated Folding & Sliding Roller Shutters |
 |
 |
-
A
complete Overhead Doors.
-
Galvanized
Steel Folding Shutter Doors.
-
Galvanized
Steel Roller Shutter Doors.
-
All
types of Fire Doors.
-
Insulated
Folding Shutter Doors.
-
Steel
Hinged Doors and Frames.
-
PVC
and Aluminum Grills.
-
PVC
Strip Doors and Rubber Crash Doors.
-
Rapid
Roll Doors.
-
Railings
and Entrance Gates.
|
 |
|
|
4
Hours Horizontal Escalator Fire Rated Shutters |
 |
 |
Supply & Installation of SKB-A7E 2 hours
fire rated motorized horizontal escalator roller
shutters c/w all necessary manufacturer
specifications, confirm to BS 476 par 22 and
approved, accepted by local Fire department.
Finishing
shall be powder coated to Approved RAL colours.
Size
: 5000mm width x 12000mm height.
|
|
|
|
|
|
|
Double
Wall Insulated Fire Rated Shutters |
 |
 |
-
For
noise & heat control.
-
This
Double Wall design shutters available in Galvanized
Steel & Aluminum with in filled with Rock wool or
polyurethane foam which are able to cut down Noise
& Heat losses.
-
To
reduce noise & friction when shutter curtain is
movement along guide rails.
-
Shutters
has developed and is producing Polyester stick-on belt
silencer and Extruded Aluminum with Mohair inserted,
which are suitable for all types of shutter guide
rails.
|
|
|
|
|
|
|